Proteomics Workflow Diagram Generator for LC-MS/MS
Generate proteomics workflow diagrams from text: lysis, trypsin digestion, LC-MS/MS, MS1 and MS2, DDA vs DIA, SILAC, TMT, database search and FDR.
Create Your Proteomics Workflow Diagram
Example: Bottom-up LC-MS/MS workflowView full sizeFree to try ·
Proteomics Workflow Diagram Examples
Five AI drafts: a bottom-up LC-MS/MS workflow, quantification strategies, DDA vs DIA, a data analysis pipeline and bottom-up vs top-down, as starting points. They are schematics, need expert review, and are not real spectra or data.
Bottom-up LC-MS/MS proteomics workflow
AI draft of a shotgun proteomics workflow. Proteins are extracted, reduced, alkylated and digested with trypsin, and the peptides are separated by reversed-phase LC and ionized by electrospray. An MS1 scan measures the precursors, selected precursors are fragmented, and an MS2 scan records the fragments. A database search and target-decoy FDR filtering lead to protein inference and quantification.
SILAC, TMT or iTRAQ, and label-free quantification
AI draft showing where each strategy enters the workflow. SILAC labels proteins metabolically during cell culture, before lysis and mixing. TMT and iTRAQ label peptides chemically after digestion, and the pooled samples are read from reporter ions in the fragment scan. Label-free runs each sample separately and compares MS1 intensity or spectral counts.
DDA vs DIA acquisition
AI draft comparing acquisition modes. In DDA, an MS1 survey scan is used to pick the most intense precursors, which are fragmented one at a time. In DIA, the instrument steps through m/z isolation windows and fragments every precursor in each window together. The small spectra are schematic, not data.
Proteomics data analysis pipeline
AI draft of the computational side. Raw spectra go through peak picking, then a database search against a protein sequence database and a decoy database. Target-decoy FDR filtering is followed by protein inference, quantification, statistical testing and pathway enrichment.
Bottom-up vs top-down proteomics
AI draft contrasting the two approaches. Bottom-up digests proteins into peptides before LC and infers proteins from peptide sequences. Top-down separates and fragments intact proteins with no digestion step, which supports proteoform-level identification.
For a sequencing-based omics figure, see the RNA-seq workflow diagram generator. For a methods overview or grant roadmap that combines several omics layers, use the research workflow diagram generator, and for a structural biology pipeline the cryo-EM workflow diagram generator. Do not use AI images to represent actual spectra or data. If a figure is for a journal, check your target journal's AI image policy first; see journal AI image policies.
What a proteomics workflow diagram has to show
Mass spectrometry-based proteomics identifies and quantifies proteins by measuring peptides or intact proteins in a mass spectrometer. A useful workflow diagram keeps the order of sample preparation, separation, ionization, mass analysis and data analysis, and shows where quantification choices such as SILAC, TMT or label-free enter. Most Methods and grant figures describe the bottom-up (shotgun) approach, in which proteins are digested into peptides before LC-MS/MS. Keep every step generic unless you are describing your own protocol, and do not print protein or peptide counts that you cannot source.
The reference logic of a bottom-up workflow
- Sample preparation: lyse cells or tissue and extract proteins, then reduce disulfide bonds (for example with DTT) and alkylate cysteines (for example with iodoacetamide).
- Digestion: a protease, most often trypsin, cleaves proteins into peptides. Trypsin cuts on the C-terminal side of lysine and arginine, and generally not before proline.
- Cleanup and fractionation: peptides are often desalted and, for deep profiling, fractionated before analysis.
- LC-MS/MS: peptides are separated by reversed-phase liquid chromatography, ionized by electrospray (ESI), and measured in an MS1 scan. Selected precursor ions are fragmented (for example by CID or HCD) and the fragments are measured in an MS2 scan.
- Identification: MS2 spectra are matched to peptide sequences in a protein database as peptide-spectrum matches (PSMs). A target-decoy search estimates the false discovery rate (FDR), commonly set at 1%, and peptides are then assembled into protein identifications.
- Quantification and interpretation: protein abundance is compared between samples, tested statistically, and interpreted with pathway or gene ontology enrichment.
Where quantification strategies enter
- SILAC is metabolic labeling. Cells are grown in media with light or heavy amino acids, so the label is added during culture, before lysis and before samples are mixed. Light and heavy peptide pairs are compared in MS1.
- TMT and iTRAQ are chemical labels added to peptides after digestion. Labeled samples are pooled and measured in one LC-MS/MS run, and the reporter ions that carry the quantitative signal appear after fragmentation, not in the MS1 scan.
- Label-free quantification adds no label. Each sample is run separately and compared by MS1 peak intensity or by spectral counts.
- Data-dependent acquisition (DDA) selects individual intense precursors from the MS1 scan for fragmentation. Data-independent acquisition (DIA), for example SWATH, fragments all precursors within each m/z window together.
Drawing choices that avoid common errors
- Put digestion before LC, and LC before ESI and MS1. Put MS1 before fragmentation and MS2 after it.
- Do not draw SILAC and TMT labeling in the same step: SILAC is in culture, TMT or iTRAQ is after digestion.
- Show the FDR as estimated with a decoy database, not as a single filter step that simply removes decoy proteins.
- Draw DDA as picking single top N precursors and DIA as fragmenting everything in each window, not the reverse.
- Keep top-down proteomics (intact proteins, no digestion) as a separate figure from bottom-up.
- Do not use AI images to represent actual spectra or data. Show real spectra and results from your own instrument and software.
Where this figure is used in research
- Methods overviews and supplementary figures that explain a proteomics pipeline.
- Grant applications and core facility proposals that lay out sample preparation through data analysis.
- Lab meetings, thesis chapters and review articles that compare quantification and acquisition strategies.
- If a figure is for a journal, check your target journal’s AI image policy first; see journal AI image policies.
How to prompt for an accurate proteomics figure
- List the steps in order: lysis, reduction and alkylation, digestion, LC, ESI, MS1, fragmentation, MS2, database search, FDR, quantification.
- Say which quantification strategy you use and where it enters: culture for SILAC, after digestion for TMT or iTRAQ, or none for label-free.
- Say whether the acquisition is DDA or DIA, and whether the workflow is bottom-up or top-down.
- Ask for no numbers, instrument brands or spectra unless you supply them.
- Check every label and arrow against your own protocol and the references below.
Frequently Asked Questions
Reference sources (checked November 2026)
- Aebersold R, Mann M. Mass spectrometry-based proteomics. Nature 2003
- Aebersold R, Mann M. Mass-spectrometric exploration of proteome structure and function. Nature 2016
- Elias JE, Gygi SP. Target-decoy search strategy for increased confidence in large-scale protein identifications by mass spectrometry. Nat Methods 2007
- Ong SE, Blagoev B, Kratchmarova I, et al. Stable isotope labeling by amino acids in cell culture, SILAC, as a simple and accurate approach to expression proteomics. Mol Cell Proteomics 2002
- Thompson A, Schäfer J, Kuhn K, et al. Tandem mass tags: a novel quantification strategy for comparative analysis of complex protein mixtures by MS/MS. Anal Chem 2003
- Gillet LC, Navarro P, Tate S, et al. Targeted data extraction of the MS/MS spectra generated by data-independent acquisition. Mol Cell Proteomics 2012
Related Research Tools

RNA-seq Workflow Diagram Generator
RNA-seq workflow diagrams: library prep, alignment, count matrix, DESeq2 and UMAP.

Research Workflow Diagram Generator
Research workflow diagrams for Methods overviews, grant roadmaps and theses.

Cryo-EM Workflow Diagram Generator
Cryo-EM workflow diagrams from grid vitrification to refinement and FSC resolution.