Structural Biology Tool

Cryo-EM Workflow Diagram Generator Vitrification to FSC

Generate cryo-EM workflow diagrams from text: grid vitrification, data collection, motion correction, CTF, 2D/3D classification and FSC. Draft figures.

Wet-lab and computational steps in separate stagesGrid vitrification, motion correction, CTF, 2D and 3D steps

Create Your Cryo-EM Workflow Diagram

Describe your cryo-EM workflow figure
574 / 20,000 characters
Start from an example
AI-generated single-particle cryo-EM workflow from protein purification and grid vitrification to data collection, image processing and model buildingExample: Single-particle workflowView full size

Free to try ·

Preview

Cryo-EM Workflow Diagram Examples

Five AI drafts: the full single-particle workflow, grid vitrification, the processing pipeline, a cryo-ET comparison and an FSC schematic. AI diagrams need expert review.

View:

Single-particle cryo-EM workflow, sample to model

AI-generated. Wet-lab steps (purification, optional negative-stain screening, vitrification, grid screening, data collection) feed the computational steps from motion correction to model building and validation.

single particlevitrificationmotion correction

Grid preparation and vitrification

AI-generated. Sample is applied to a grid, excess liquid is blotted away, and the grid is plunged into liquid ethane so the water forms vitreous (non-crystalline) ice around the particles.

plunge freezingblottingliquid ethane

Cryo-EM data processing pipeline

AI-generated. Movies are motion-corrected, CTF parameters are estimated, particles are picked and cleaned by 2D classification, and an initial 3D model is refined into a final map.

CTFparticle picking2D classification

Single-particle cryo-EM vs cryo-ET

AI-generated. Single-particle analysis averages many views of purified particles; cryo-ET images one thin specimen at many tilt angles to build a tomogram, optionally followed by subtomogram averaging.

cryo-ETtilt seriestomogram

FSC curve and the 0.143 criterion

AI-generated schematic, not real data. The FSC between two independently refined half-maps falls with spatial frequency; the resolution is read where the curve crosses the 0.143 threshold.

FSChalf-maps0.143

This page is a focused companion to the workflow diagram generator. For a sequencing-based method, see the RNA-seq workflow diagram generator, and for the molecules you are imaging, the protein structure diagram generator.

What a cryo-EM workflow diagram has to show

A single-particle cryo-EM workflow figure usually has two halves. The wet-lab half covers protein purification, optional negative-stain screening, grid preparation and vitrification by plunge freezing, grid screening, and data collection on a transmission electron microscope with a direct electron detector that records movies. The computational half covers motion correction, contrast transfer function (CTF) estimation, particle picking, 2D classification, an ab initio initial model, 3D classification and refinement, resolution assessment, and atomic model building and validation. Methods sections, grant applications and facility pages draw this as one linear flow with the two halves clearly separated.

The order that matters

  • Vitrification comes before imaging: the sample is frozen in vitreous ice on the grid first, then screened, then used for data collection.
  • Motion correction aligns the frames of each movie before CTF estimation, and both come before particle picking.
  • 2D classification removes poor or junk particles before an initial 3D model and 3D refinement.
  • Resolution is commonly reported from the Fourier shell correlation (FSC) between two independently refined half-maps, using the 0.143 criterion. Model building and validation follow the final map.
  • Cryo-electron tomography (cryo-ET) is a separate branch: it collects a tilt series of one specimen to reconstruct a tomogram, and may add subtomogram averaging. Keep it distinct from single-particle analysis.

Where this figure is used

  • Methods figures and graphical summaries in structural biology papers.
  • Grant and core-facility proposals that explain a cryo-EM pipeline to reviewers.
  • Review articles and thesis chapters on single-particle analysis.
  • Facility onboarding material and talks for new users of a cryo-EM platform.

How to prompt for an accurate cryo-EM figure

  • Say which workflow you want: single-particle analysis, grid preparation only, data processing only, or a single-particle vs cryo-ET comparison.
  • List the steps in order, with wet-lab steps and computational steps named separately.
  • Name software only as an example, such as RELION or cryoSPARC, and only if your figure needs it.
  • Ask for each label once and for arrows that follow the order you give.
  • Check every step name and arrow against a primary method source before use. The sources below are a starting point.