Epigenomics Tool

ChIP-seq Workflow Diagram Generator Crosslink to peaks

Generate ChIP-seq workflow diagrams from text: crosslinking, IP, input control, library prep, alignment and peak calling. Compare CUT&RUN and CUT&Tag.

Wet-lab workflow and analysis pipelineInput control and peak calling branches

Create Your ChIP-seq Workflow Diagram

Describe your ChIP-seq workflow figure
443 / 20,000 characters
Start from an example
AI-generated ChIP-seq wet-lab workflow from formaldehyde crosslinking and chromatin fragmentation to immunoprecipitation, DNA purification, library preparation and sequencing, with an input control branchExample: Wet-lab workflowView full size

Free to try ·

Preview

ChIP-seq Workflow Diagram Examples

Five AI drafts: the wet-lab workflow, the analysis pipeline, crosslinking and IP, a CUT&RUN and CUT&Tag comparison, and a peak-track schematic. AI diagrams need expert review.

View:

ChIP-seq wet-lab workflow with input control

AI-generated. Cells are crosslinked, lysed and fragmented; the antibody pull-down is washed and eluted, crosslinks are reversed, and the DNA goes to library preparation and sequencing. The input control is taken after fragmentation and processed without antibody.

crosslinkingsonicationimmunoprecipitation

ChIP-seq analysis pipeline

AI-generated. Reads are quality-checked, aligned and filtered, then peaks are called against the input control, for example with MACS2, before annotation, motif analysis and differential binding analysis.

FASTQalignmentMACS2

Crosslinking and immunoprecipitation

AI-generated schematic. Formaldehyde crosslinks the protein to DNA first, chromatin is then fragmented, the target is pulled down with an antibody on beads, and crosslinks are reversed to release the enriched DNA.

formaldehydesonicationProtein A/G beads

ChIP-seq vs CUT&RUN vs CUT&Tag

AI-generated. ChIP-seq crosslinks, fragments and pulls down chromatin. CUT&RUN and CUT&Tag work in permeabilized cells without crosslinking: protein A-MNase cuts at the antibody-bound site in CUT&RUN, and protein A-Tn5 inserts adapters there in CUT&Tag.

CUT&RUNCUT&TagpA-MNase

Peak calling against an input control

AI-generated schematic, not real data. Regions where the ChIP signal rises well above the input control background are called as peaks and can then be annotated against nearby genes.

peak callinginput controlTSS

This page is a focused companion to the workflow diagram generator. For expression profiling, see the RNA-seq workflow diagram generator, and to draw the pathway upstream of a transcription factor, the signaling pathway diagram generator.

What a ChIP-seq workflow diagram has to show

Chromatin immunoprecipitation followed by sequencing (ChIP-seq) maps where a protein, such as a transcription factor, or a histone modification sits on the genome. A workflow figure for a paper, grant or methods chapter usually has a wet-lab half and an analysis half. The wet-lab half runs from formaldehyde crosslinking, cell lysis and chromatin fragmentation by sonication or MNase digestion, through immunoprecipitation with an antibody, to reversal of crosslinks, DNA purification, library preparation and sequencing. The analysis half runs from quality control and alignment to peak calling, followed by annotation, motif analysis and differential binding.

The order and controls that matter

  • In crosslinked ChIP, crosslinking comes first, before lysis and fragmentation, and crosslinks are reversed only after the immunoprecipitation. Native ChIP, often used for histone marks, skips crosslinking and fragments chromatin with MNase.
  • An input DNA control, taken from fragmented chromatin before immunoprecipitation, is processed without antibody. Peak calling, for example with MACS2, uses it as the background. A control IP with a non-specific IgG is another common control.
  • Antibody quality drives the result, so many workflow figures note the antibody and its target explicitly.
  • Alignment and filtering come before peak calling; annotation and motif analysis come after.
  • CUT&RUN and CUT&Tag are related methods that work in permeabilized cells without crosslinking and need less starting material. CUT&RUN uses protein A-MNase to cut DNA at the antibody-bound site, and CUT&Tag uses protein A-Tn5 to insert sequencing adapters there. Draw them as a comparison, not as extra ChIP-seq steps.

Where this figure is used

  • Methods figures and graphical summaries in epigenetics and genomics papers.
  • Grant aims that profile transcription factor binding or histone marks.
  • Thesis chapters and review articles that compare chromatin profiling methods.
  • Core facility protocols and training slides for new users.

How to prompt for an accurate ChIP-seq figure

  • Say whether you want the wet-lab workflow, the analysis pipeline, the crosslinking and IP schematic, or a method comparison.
  • List the steps in order, and say where the input control branches off and where it rejoins.
  • Name the target (a transcription factor or a histone mark) and the tools only if your figure needs them.
  • Ask for each label once and for arrows that do not cross.
  • Check every step and control against a primary method source before use. The sources below are a starting point.

Frequently Asked Questions

Reference sources (checked November 2026)